Data Sheet
{{@273}}
|
TCX IMX8
|
Features:
|
Specifications
|
Redisage PN |
LCX01 |
LCX02 |
LCX03 |
LCX04 |
LCX05 |
LCX06 |
|
|
Version |
Light |
Light GSM |
Basic |
Basic GSM |
Max |
Max GSM |
|
|
Power input |
12-24 VDC +-20%, maximum power 25 W, reverse polarity protection | ||||||
|
System on Module |
VAR-SOM-MX8: NXP iMX8M-MINI | ||||||
|
Core |
NXP’s i.MX 8M Mini with 1.6 GHz Quad-core ARM Cortex-A53 and 400 MHz Cortex-M4 real-time processor | ||||||
|
Timing |
1.6 GHz | ||||||
|
RAM |
2 GB DDR4 | ||||||
|
Flash eMMC |
16GB | ||||||
|
Ports/ Connectors |
RS232 |
2x |
2x |
2x |
2x |
2x |
2x |
|
terminal block max. 2.5 mm2 wire max. 15 m at 115.2 kbps |
|||||||
|
RS485 |
2x |
2x |
2x |
2x |
4x |
4x |
|
| terminal block max. 2.5 mm2 wire max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps |
|||||||
|
Digital Input |
|
|
5x |
3x |
5x |
3x |
|
|
Digital Input/Output |
7x |
7x |
7x |
7x |
7x |
7x |
|
|
Universal Input/Output |
|
|
4x Voltage Input) |
4x (Current Input, Voltage Input) |
4x (Current Input, Voltage Input, |
4x (Current Input, Voltage Input, |
|
|
USB type A |
|
|
|
|
|
|
|
|
microUSB |
|
|
|
|
|
|
|
|
1-Wire |
|
|
|
|
|
|
|
|
microHDMI |
|
|
|
|
|
|
|
|
microSD |
|
|
|
|
|
|
|
|
Ethernet |
10/100 Mb/s Base-T, RJ45 connector | ||||||
|
Wi-Fi® 2.4/5 GHz 802.11b/g/n/ac SMA Antenna connector |
|
|
|
|
|||
|
GSM |
|
|
|
|
|
|
|
|
Joystick |
|
|
|
|
|
|
|
|
Display OLED 0.87'' 128x32 px black&white |
|
|
|
|
|
|
|
|
Watchdog |
Software WDT on external ESP32 microcontroller | ||||||
|
Secure chip |
|
|
|
|
|
|
|
|
TPM |
|
|
|
|
|
|
|
|
RTC module |
|
|
|
|
|
|
|
|
Buzzer |
|
|
|
|
|
|
|
|
External Flash |
|
|
|
|
|
|
|
|
EEPROM |
|
|
|
|
|
|
|
|
OS |
Embedded Linux | ||||||
|
Dimensions [mm] |
119 x 101 x 22.5 | ||||||
|
Work temperature [°C] |
-40 to +75 | ||||||
|
| |||||||
Certification |
|||||||
|
Norms |
Check here | ||||||
{{@274#bkmrk-placement-of-periphe}}
{{@274#bkmrk-}}
{{@169}}
Enclosure
The space that the device occupies can be approximated to a cube of the following dimensions: 119 mm x 101 mm x 35,3 mm.
{{@274#bkmrk--6}}
Norms
EMC standards
| Standard | Title | Description | Comments |
| Emission |
|||
| EN 61000-6-4 | Generic Emission Standard | Emission standard for industrial environment | |
| EN 55011 | Conducted Emission | Limits for Group 1, Class A | Power port |
| EN 55011 | Radiated Emission | Limits for Group 1, Class A | |
| EN 55032 | Conducted Emission | Limits for Class A | Ethernet port |
| Immunity |
|||
| EN 61000-6-2 | Generic Emission Standard | Immunity standard for industrial environment | |
| EN 61000-4-2 | Electrostatic discharge (ESD) | ±4kV (contact discharge), ±8kV (air discharge) | |
| EN 61000-4-3 | Radio Frequency immunity | 10V/m | |
| EN 61000-4-4 | Burst/EFT immunity | ±1kV | All ports |
| EN 61000-4-5 | Surge immunity | ±0.5kV (line-to-line), ±1kV (line-to-earth) | Power port |
| EN 61000-4-29 | Voltage Dips, Short Interruptions and Voltage Variations | In progress | Power port |
Climatic standards
| Standard | Title | Description | Comments |
| EN 61131-2 | Product Standard | Programmable controllers - Part 2: Equipment requirements and tests | |
| EN 60068-2-1 | Cold (storage) | Cold test “storage” suitable for non-heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for transport or storage at low temperatures. | |
| EN 60068-2-2 | Dry Heat (storage) | Dry heat test “storage” suitable for non-heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for transport or storage at high temperatures. |
|
| EN 60068-2-1 | Cold (operation) | Cold test “operation” suitable for heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for operation at low temperatures. | |
| EN 60068-2-2 | Dry Heat (operation) | Dry heat test “operation” suitable for heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for operation at high temperatures. | |
| EN 60068-2-14 | Change of temperature (storage) | The change of temperature test “storage” is suitable for non-heat emitting products. The objective of this test is limited to determining the suitability of the components, devices, or products for operation during temperature changes. | |
| EN 60068-2-14 | Change of temperature (operation) | The change of temperature test “operation” is suitable for heat emitting products. The objective of this test is limited to determining the suitability of the components, devices, or products for operation during temperature changes. | |
| Redisage | Cold start | Cold start test is suitable for non-heat emitting products just before starting the device. The objective of this test is limited to determining the suitability of the devices for start in cold conditions. | |
| EN 60068-2-30 | Damp Heat (storage) | Damp heat test “storage” is suitable for non-heat emitting products. The objective of this test is limited to determining the suitability of the devices for transport or storage under cyclic damp heat conditions. | |
| EN 60068-2-30 | Damp Heat (operation) | Damp heat test “operation” is suitable for non-heat emitting products. The objective of this test is limited to determining the suitability of the devices for transport or storage under cyclic damp heat conditions. |