Data Sheet
Tiger City IMX Industrial Computer with Linux OS
The Tiger City IMX minicomputer uses Linux operating systems and is equipped with several communication interfaces such as: Ethernet, USB 2.0, HDMI, GSM, RS232, RS485, 1-Wire and multiple analog-digital inputs and outputs. It can also be configured to include a Wi-Fi module and encryption modules that increase the security of the device. The casing enables installation on the DIN rail. The front panel has switches, an OLED display and a joystick for manual control of the device operation.
|
TCX IMX8
|
Features:
|
Specifications
|
Redisage PN |
LCX01 |
LCX02 |
LCX03 |
LCX04 |
LCX05 |
LCX06 |
|
|
Version |
Light |
Light GSM |
Basic |
Basic GSM |
Max |
Max GSM |
|
|
Power input |
12-24 VDC +-20%, maximum power 25 W, reverse polarity protection | ||||||
|
System on Module |
VAR-SOM-MX8: NXP iMX8M-MINI | ||||||
|
Core |
NXP’s i.MX 8M Mini with 1.6 GHz Quad-core ARM Cortex-A53 and 400 MHz Cortex-M4 real-time processor | ||||||
|
Timing |
1.6 GHz | ||||||
|
RAM |
2 GB DDR4 | ||||||
|
Flash eMMC |
16GB | ||||||
|
Ports/ Connectors |
RS232 |
2x |
2x |
2x |
2x |
2x |
2x |
|
terminal block max. 2.5 mm2 wire max. 15 m at 115.2 kbps |
|||||||
|
RS485 |
2x |
2x |
2x |
2x |
4x |
4x |
|
| terminal block max. 2.5 mm2 wire max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps |
|||||||
|
Digital Input |
|
|
5x |
3x |
5x |
3x |
|
|
Digital Input/Output |
7x |
7x |
7x |
7x |
7x |
7x |
|
|
Universal Input/Output |
|
|
4x Voltage Input) |
4x (Current Input, Voltage Input) |
4x (Current Input, Voltage Input, |
4x (Current Input, Voltage Input, |
|
|
USB type A |
|
|
|
|
|
|
|
|
microUSB |
|
|
|
|
|
|
|
|
1-Wire |
|
|
|
|
|
|
|
|
microHDMI |
|
|
|
|
|
|
|
|
microSD |
|
|
|
|
|
|
|
|
Ethernet |
10/100 Mb/s Base-T, RJ45 connector | ||||||
|
Wi-Fi® 2.4/5 GHz 802.11b/g/n/ac SMA Antenna connector |
|
|
|
|
|||
|
GSM |
|
|
|
|
|
|
|
|
Joystick |
|
|
|
|
|
|
|
|
Display OLED 0.87'' 128x32 px black&white |
|
|
|
|
|
|
|
|
Watchdog |
Software WDT on external ESP32 microcontroller | ||||||
|
Secure chip |
|
|
|
|
|
|
|
|
TPM |
|
|
|
|
|
|
|
|
RTC module |
|
|
|
|
|
|
|
|
Buzzer |
|
|
|
|
|
|
|
|
External Flash |
|
|
|
|
|
|
|
|
EEPROM |
|
|
|
|
|
|
|
|
OS |
Embedded Linux | ||||||
|
Dimensions [mm] |
119 x 101 x 22.5 | ||||||
|
Work temperature [°C] |
-40 to +75 | ||||||
|
Safety measures |
|||||||
|
Certification |
|||||||
|
Norms |
Check here | ||||||
Placement of peripherals

Frame ground FG
Electronic circuits are constantly prone to electrostatic discharge ESD. Redisage Electronics modules feature a design for the frame ground terminal block FG. The frame ground provides a path for bypassing ESD, which provides enhanced static protection ESD abilities and ensures the module is more reliable. Connecting FG terminal block to the earth ground will bypass the ESD disturbances outside the device so will provide a better level of protection against ESD.
Frame Ground FG connection reference drawing is provided below.

If earth ground is not available FG can be left floating or it can be connected with the power supply GND.
Enclosure
The space that the device occupies can be approximated to a cube of the following dimensions: 119 mm x 101 mm x 35,3 mm.
Norms
EMC standards
| Standard | Title | Description | Comments |
| Emission |
|||
| EN 61000-6-4 | Generic Emission Standard | Emission standard for industrial environment | |
| EN 55011 | Conducted Emission | Limits for Group 1, Class A | Power port |
| EN 55011 | Radiated Emission | Limits for Group 1, Class A | |
| EN 55032 | Conducted Emission | Limits for Class A | Ethernet port |
| Immunity |
|||
| EN 61000-6-2 | Generic Emission Standard | Immunity standard for industrial environment | |
| EN 61000-4-2 | Electrostatic discharge (ESD) | ±4kV (contact discharge), ±8kV (air discharge) | |
| EN 61000-4-3 | Radio Frequency immunity | 10V/m | |
| EN 61000-4-4 | Burst/EFT immunity | ±1kV | All ports |
| EN 61000-4-5 | Surge immunity | ±0.5kV (line-to-line), ±1kV (line-to-earth) | Power port |
| EN 61000-4-29 | Voltage Dips, Short Interruptions and Voltage Variations | In progress | Power port |
Climatic standards
| Standard | Title | Description | Comments |
| EN 61131-2 | Product Standard | Programmable controllers - Part 2: Equipment requirements and tests | |
| EN 60068-2-1 | Cold (storage) | Cold test “storage” suitable for non-heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for transport or storage at low temperatures. | |
| EN 60068-2-2 | Dry Heat (storage) | Dry heat test “storage” suitable for non-heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for transport or storage at high temperatures. |
|
| EN 60068-2-1 | Cold (operation) | Cold test “operation” suitable for heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for operation at low temperatures. | |
| EN 60068-2-2 | Dry Heat (operation) | Dry heat test “operation” suitable for heat emitting products. The object of the test is limited to determining the suitability of the components, devices or products for operation at high temperatures. | |
| EN 60068-2-14 | Change of temperature (storage) | The change of temperature test “storage” is suitable for non-heat emitting products. The objective of this test is limited to determining the suitability of the components, devices, or products for operation during temperature changes. | |
| EN 60068-2-14 | Change of temperature (operation) | The change of temperature test “operation” is suitable for heat emitting products. The objective of this test is limited to determining the suitability of the components, devices, or products for operation during temperature changes. | |
| Redisage | Cold start | Cold start test is suitable for non-heat emitting products just before starting the device. The objective of this test is limited to determining the suitability of the devices for start in cold conditions. | |
| EN 60068-2-30 | Damp Heat (storage) | Damp heat test “storage” is suitable for non-heat emitting products. The objective of this test is limited to determining the suitability of the devices for transport or storage under cyclic damp heat conditions. | |
| EN 60068-2-30 | Damp Heat (operation) | Damp heat test “operation” is suitable for non-heat emitting products. The objective of this test is limited to determining the suitability of the devices for transport or storage under cyclic damp heat conditions. |
Additional notes
Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
| Related information and links |
||
| Ordering information | Accessories | Similar products |
Products family sample photo

DISCLAMER NOTES
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.