Skip to main content

Data Sheet

Tiger City IMX Industrial Computer with Linux OS

The Tiger City IMX minicomputer uses Linux operating systems and is equipped with several communication interfaces such as: Ethernet, USB 2.0, HDMI, GSM, RS232, RS485, 1-Wire and multiple analog-digital inputs and outputs. It can also be configured to include a Wi-Fi module and encryption modules that increase the security of the device. The casing enables installation on the DIN rail. The front panel has switches, an OLED display and a joystick for manual control of the device operation.

TCX IMX8

 

image.png

Features:

  • Power: voltage 12-24 VDC +-20%, maximum power 25 W, reverse polarity protection
  • SoM: VAR-SOM-MX8M-MINI
  • Core: NXP’s i.MX 8M Mini with 1.6 GHz Quad-core ARM Cortex-A53 and 400 MHz Cortex-M4 real-time processor
  • Timing: 1.6 GHz
  • RAM: 2 GB DDR4
  • Flash eMMC: 16 GB
  • 1 x microSD connector
  • 1 x microHDMI 1.3a
  • 1 x microUSB 2.0 HOST / OTG, max. 500 mA
  • 1 x USB-A 2.0 HOST, max. 1 A
  • 1 x modem GSM SIM7600E + microSIM
  • 1 x 1-Wire
  • 7 x DIO - digital input/output, max. 30 V
  • 4 x UIO - universal analog-digital input/output (temperature measurement with sensors, e.g.: Pt1000, Ni1000, KTY, NTC, current, voltage and resistance sensors), max. 20 V
  • 5 x DI - digital input (3 x DI), max. 30 V
  • 2 x RS232/RS485, baudrate 50-115200 bps
  • 2 x RS485, baudrate 50-115200 bps
  • 1 x Ethernet 10/100 Mbps - RJ45 connector
  • 1 x WiFi / Bluetooth module (optional)
  • 1 x secure element (optional)
  • 1 x display OLED 0.87" 128x32 px black&white
  • RTC, buzzer, EEPROM
  • Software watchdog

 

Placement of peripherals

Frame ground FG

Electronic circuits are constantly prone to electrostatic discharge ESD. Redisage Electronics modules feature a design for the frame ground terminal block FG. The frame ground provides a path for bypassing ESD, which provides enhanced static protection ESD abilities and ensures the module is more reliable. Connecting FG terminal block to the earth ground will bypass the ESD disturbances outside the device so will provide a better level of protection against ESD.

Frame Ground FG connection reference drawing is provided below.

If earth ground is not available FG can be left floating or it can be connected with the power supply GND.

Enclosure