Skip to main content

Hardware

RemoteCOM can be installed on any device from the Redisage C20 - C25 Ethernet Converters family.

Features

Features

c5368820-11b3-4934-ae6d-774d7208eae7.png

Ethernet converter to RS232/RS485

ESD protection for the RS485 data line

Power supply: +12 to +30 VDC

Transmission speed up to 115200 bps

Tx, Rx and power LED indicators

RS485 embedded termination 120 ohm

Operating temperatures: -40°C to +75°C

DIN rail mounting

Dimensions: 90x56.4x22.5 mm

3 years warranty

Customization of OEM is welcomed

Frame ground FG

Electronic circuits are constantly prone to electrostatic discharge ESD.

Redisage Electronics modules feature a design for the frame ground terminal block FG.

The frame ground provides a path for bypassing ESD which provides enhanced static protection ESD abilities and ensures the module is more reliable.

Connecting FG terminal block to the earth ground will bypass the ESD disturbances outside the device so it will provide a better level of protection against ESD.

Frame Ground FG connection reference drawing is provided below.

If earth ground is not availabe FG can be left floating or it can be connected with power supply GND.

Specification

Redisage PN

C20

C21

C22

C23

C24

C25

Ports

RS232

2x

-

-

4x

-

2x

RS485

-

1x

-

-

4x

2x

RS232/RS485

-

-

2x

-

-

-

Microcontroller

ESP32

STM32F4

WiFi

N/A

Power

Voltage

12-30 VDC

Power

< 1 W

Frame ground connection

yes

Baud rate

up to 115200 bps

LED indicators

communication Tx, Rx and power

RS485 termination

120 ohm manually enabled

Connector

RS232/RS485

8 pin terminal block max. 2.5 mm2 wire

Power

3 pin terminal block max. 2.5 mm2 wire

Ethernet

RJ45

Transmission
distance

RS485

max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps
(Belden 9841 2P twisted-pair cable, if different cables are used,
the transmission distance may change)

RS232

max. 15 m at 115.2 kbps

Mounting and enclosure

DIN rail, plastic PA - UL 94 V0, black/green

Temperatures

-40°C to +75°C operating and storage

Humidity

10 - 90% RH, non-condensing

ESD protection

±4 kV contact discharge / ±8 kV air discharge

Certification 

CE, RoHS

LED indicators

Converters C20 - C22

Converters C23 - C25

20708068-859a-46bf-8b76-783b7400789a.png 66a7b90e-9af7-4b47-ae63-40409f98a845.png

LED indicator

Color

Function

LED indicator

Color

Function

PW

Blue

Power

PW

Blue

Power

ETH

Green

Network activity

ETH

Green

Network activity

ST

Orange

Console mode

CN

Yellow

Console mode

Red

Service mode

COM

Green

RS232/RS485 activity

 

SR

Red

Service mode

ER

Yellow

Error

Pin assignments

C20

cb11de82-9b9c-441b-a5ec-a154b2974af1.png

C21

9ec3cdd8-81fa-43f3-b5d6-321d3e380273.jpg

C22

b256a7e1-4bcb-44a8-8d61-d9973cc82d4e.png

C23

c0d89b16-0d72-4553-aacd-745659a94c87.png

C24

939889bb-f557-4d08-b093-d2ac790a3bce.png

C25

46bb1368-b158-4f8d-8114-304a359a9685.png

In the C22 converter user should use only RS232 or only RS485 interface of one port as they occupy the same internal bus of the device.