Data Sheet
C14 |
Features
|
Introduction
In a remote data communication between a computer and a peripheral equipment, it is often required to make an interconversion between standard serial interfaces. Compatible with RS232C / RS485 standards, the Passive Serial Converter is able to convert mono-end RS232 signal to balance differential RS485 signal and extend the communication distance up to 1.2 km.
No external power is needed as it adopts a particular RS232 charge pump to drive the system and gain electricity without initializing the RS232 serial interface. An internal zero delay auto transceiver and particular I/O circuits automatically control the data stream direction without any handshake signal (for example RTS, DTR, etc.). Thereby it guarantees to function under RS485 standard without changing the program compiled under RS232 half-duplex mode and assures the adaptation to a current operation software and interface hardware.
It implements multi-machine response communication and is commonly used in industrial automation control systems, all-one-card, access control systems, consumption systems, time and attendance systems, parking systems, self-service banking systems, bus charging systems, highway toll station systems and so on.
Specifications
Redisage PN |
C14 | |
Converter ports |
1 x RS232 & 1 x RS485 | |
Power |
Voltage | Passive |
Power | < 1 W | |
Frame ground protection | yes | |
Serial interface |
RS232 | TxD, RxD, GND |
RS485 | A, B | |
Baud rate |
up to 115200 bps | |
LED indicators |
N/A | |
RS485 termination |
N/A | |
Connector |
RS232 | DB9 male connector |
RS485 | 3 pin terminal block max. 2.5 mm2 wire |
|
Power | N/A | |
Transmission distance |
RS485 | max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps (Belden 9841 2P twisted-pair cable, if different cables are used, the transmission distance may change) |
RS232 | max. 15 m at 115.2 kbps |
|
Mounting and enclosure |
compact | |
Temperatures | -40°C to +75°C operating and storage |
|
Humidity | 10 - 90% RH, non-condensing |
|
ESD protection |
±4 kV contact discharge / ±8 kV air discharge |
|
Certification |
CE, RoHS |
Connector and signal
RS232C pin distribution
DB9 Female ( |
RS-232C Interface Signal |
1 |
Protective |
2 |
RXD SIN |
3 |
TXD SOUT |
4 |
DTR |
5 |
GND |
6 |
DSR |
7 |
RTS |
8 |
CTS |
9 |
RI |
RS485 data output & connector and pin distribution
DB9 Male (PIN) |
Data Output |
RS-485 Half Duplex |
1 |
T/R+ |
RS485 (A+) |
2 |
T/R- |
RS485 (B-) |
3 |
GND |
Ground wire |
4 |
VCC |
9 VDC |
Applications
C14 - Non Isolated (Passive)
Product dimensions
Troubleshooting
Data communication failure
- Check if the RS232 interface connection is correct.
- Check if the RS232 output connection is correct.
- Check if connection ends are well-connected.
Data loss or mistake
- Check if data rate and format is consistent on both communication ends.
Additional notes
Related information and links |
||
Ordering information | Accessories | Similar products |
Products family sample photo
DISCLAMER NOTES
ALL PRODUCT, PRODUCT SPECIFICATIONS, AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.