Data Sheet
Modbus gateways allow data transmission between LAN hosts and serial devices by converting Modbus protocols (Modbus TCP and Modbus RTU/ASCII). They are intended to be used in industrial networks especially in the field of Industry 4.0 but not only. Apart from extending the capabilities of industrial devices, they can be also adapted up to user’s requirements and needs.
Transmission is carried out by two modes: Gateway and Router. In the Gateway mode the port is used to communicate with Slave devices, but in the Router mode with Master devices. It is also possible to set up different modes on every port. Block diagrams below describe how each of these modes works.
Introduction
Devices are based on G01 - G03 gateways (ESP32 Xtensa LX6 microcontroller) and G14 - G16 gateways (STM32F4 microcontroller) depending on needed ports and interfaces.
Dedicated EMC integrated circuits guarantee improved connection quality by limiting the impact of interference typical for an industrial environment.
{{@175#bkmrk-specification}}
{{@175#bkmrk-redisage-pn-g01-g02-}}
Variants
G01 - Ethernet Modbus Gateway 2 x RS232
G02 - Ethernet Modbus Gateway 1 x RS485
G03 - Ethernet Modbus Gateway 2 x RS232/RS485
In the G03 gateway user should use only RS232 or only RS485 interface of one port as they occupy the same internal bus of the device.
G14 - Ethernet Modbus Gateway 4 x RS232
G15 - Ethernet Modbus Gateway 2 x RS232 & 2 x RS485
G16 - Ethernet Modbus Gateway 4 x RS485
{{@169#bkmrk-frame-ground-fg}}
{{@169#bkmrk-electronic-circuits-}}
{{@169#bkmrk-frame-ground-fg-conn}}
{{@169#bkmrk-if-earth-ground-is-n}}
{{@175#bkmrk-pin-assignments}}
{{@175#bkmrk-g01-g02-g03-g14-g15-}}
Enclosure dimensions
U Module Enclosure.
98 x 22.5 x 56.4
Units: mm.
Getting started
Power supply
Ethernet Modbus gateways G01 - G03 and G14 - G16 have wide voltage power input (12 - 30 VDC). The power consumption is less than 1 W.
LED indicators
Ethernet Modbus gateways G01 - G03 have 3 LED indicators:
- PW LED Blue - Power
- ETH LED Green - Network activity
- ST LED Orange - USB-UART Serial console mode
Ethernet Modbus gateways G14 - G16 have 5 LED indicators:
- PW LED Blue - Power
- ER LED Yellow - Error
- ETH LED Green - Network activity
- COM LED Green - RS232/RS485 activity
- CN LED Yellow - Console mode
- SR LED Red - Service mode
Configuration by the Web Page
Default configuration of the Ethernet Modbus gateways:
- IP address: 192.168.100.100
- Subnet mask: 255.255.255.0
- Gateway: 192.168.100.1
- DNS 1: 192.168.100.1
- DNS 2: 8.8.8.8
Default login details:
- User name: admin
- Password: admin123
To access to the web page open the web browser, type the IP address in the address bar and log in using the default user name and password. The device and a PC must be connected to the same Local Area Network.
After successful login, the “Status” page will show the current status of the ports.
To change the user name and password click on the user icon and select “Edit user”.
Ports configuration is available on the “Ports” page.
{{@175#bkmrk-item-description-int}}
Changing port’s service closes all sockets connected to the ports.
Changing port’s service closes all sockets connected to the ports.
Network settings can be changed on the “Network” page.
{{@175#bkmrk-item-description-hos}}
On the “Device” page there are tools used to a firmware update, a factory reset and a device reboot. There is also basic information about the device.
{{@175#bkmrk-item-description-fir}}
Configuration by the Serial Console
The device has the ability to be reconfigured via a serial console. In case of the G01 - G03 Modbus gateways an additional USB/UART converter is needed.
For G01 - G03 gateways
- Turn off the power of the device.
- Connect Ethernet converter to the dedicated USB/UART converter via the microUSB port.
- Connect the USB/UART converter to the PC.
- Open the serial console (default baud rate is 115200 bps).
- Press and hold the S1 button.
- Turn on the power.
- Wait until the ST indicator (orange LED) lights up (it should light up after red light - service mode).
- Release the S1 button.
- Login using user’s personal credentials or default login details.
- If the process is successful, configuration command can be typed into the terminal.
For G14 - G16 gateways
- Install STM32 Virtual COM Port Driver.
- Turn off the power of the device.
- Connect Ethernet converter directly to the PC (the dedicated USB/UART converter is not obligatory).
- Open the serial console (default baud rate is 115200 bps).
- Press and hold the S1 button.
- Turn on the power.
- Wait until the ST indicator (yellow LED) lights up.
- Release the S1 button.
- Login using user’s personal credentials or default login details.
- If the process is successful, configuration command can be typed into the terminal.
Once this is done, log in using the default username and password, then change the network settings using "ipconfig" command.
{{@175#bkmrk-list-of-all-commands}}
{{@175#bkmrk-command-description-}}
{{@176#bkmrk-modbus-ports-configu}}
{{@176#bkmrk-modbus-modbus-helppr}}
modbusmodbus helpPrint command help.modbus int_addr VALUESet internal Modbus address.Example:modbus int_addr 5modbus idlet VALUEShow or set the idle TIME (in seconds) of the TCP connection after which the TCP connection is terminated by the converter and the TCP socket is released.Example:modbus idlet 720If a subcommand that normally sets a value is not given an argument, it will print the current value.Example:modbus idletSet idle time is 5000
modbus_portsmodbus_ports helpPrint command help, does not require com_number.modbus_ports PORT_NUMBER add_slaves [SLAVE_ADDR ;/- SLAVE_ADDR, *]Set all addresses of slaves connected to com_port. A star in value means fill rest free slaves. It means all slaves that are not set to other ports will be set to this one.Example:modbus_ports 1 addslaves 124Example:modbus_ports 1 addslaves 12-124Example:modbus_ports 1 addslaves 12;14;18Example:modbus_ports 1 addslaves 12;14-17;150-200Example:modbus_ports 1 addslaves 12;14-17;150-200, *modbus_ports PORT_NUMBER show_slavesShow addresses of slaves connected to com_port.Example:modbus_ports 1 showslavesmodbus_ports PORT_NUMBER mode [ascii/rtu]Set Modbus port mode to ASCII or RTU.Example:modbus_ports 2 mode asciimodbus_ports PORT_NUMBER baud [RATE]Set the baud rate to RATE. For a list of acceptable baud rates, please refer to the manual.Example:modbus_ports 1 baud 9600modbus_ports PORT_NUMBER bits [CPS]Set bit count to C, parity to P, and stop bits to S. Valid values are:C: 7, 8 or 9P: N, E or O (N- none, E- even, O- odd)S: 1 or 2Example:modbus_ports 1 bits 8N1Example:modbus_ports 2 bits 7O1modbus_ports PORT_NUMBER state [GATEWAY/ROUTER/DISABLE]Enable or disable uart functionality.Example:modbus_ports 1 state GATEWAYExample:modbus_ports 2 state DISABLEmodbus_ports PORT_NUMBER termination [on/off]Enable or disable termination on RS485 port.Example:modbus_ports 1 termination onmodbus_ports PORT_NUMBER slave_response_timeout TIMEOUTSet response timeout (serial slave) in ms. When this timeout expires, delayed frames are dropped.Example:modbus_ports 1 slave_response_timeout 2000If a subcommand that normally sets a value is not given an argument, it will print the current value.Example:modbus_ports 2 baudSet baud rate is 115200
PORT_NUMBER is a number of ports in modbus gateway and it is counted from 0.
modbus_routingmodbus_routing helpPrint routing's help.modbus_routing showDisplay all active routing table in system.[LP]: [SLAVES NUMBERS] [IP/HOSTNAME] [PORT] [TIMEOUT]modbus_routing add SLAVE_ADDR HOSTNAME PORT TIMEOUTSLAVE_ADDR with HOSTNAME PORT is used by uarts working in Modbus router mode. TIMEOUT (in ms) is used to close the connection if a slave is not responding. The maximum records is 8. One record for one address/ip.Example:modbus_routing add 18 192.168.0.10 502 2000Example:modbus_routing add 18;25 192.168.0.10 502 2000Example:modbus_routing add 18-25 192.168.0.10 502 2000Example:modbus_routing add 18-25;* 192.168.0.10 502 2000Example:modbus_routing add 18-25 modbus.local 502 2000modbus_routing remove [HOSTNAME_NUMBER/all]Remove Modbus Routing Table record. HOSTNAME_NUMBER is line number from /show/ command.Example:modbus_routing remove 2Example:modbus_routing remove all
Network settings
The following commands might be helpful to change network settings according to target LAN parameters,
ipconfigipconfig addr ADDRESSSet IP address to ADDRESS.Example:ipconfig addr 192.168.0.10ipconfig mask NETMASKSet subnet mask to NETMASK (in dot-decimal format).Example:ipconfig mask 255.255.255.0ipconfig mask BIT_COUNTSet subnet mask to BIT_COUNT bits.Example:ipconfig mask 24ipconfig gateway GATEWAY_IPSet network gateway to GATEWAY_IP.Example:ipconfig gateway 192.168.0.1ipconfig dhcp [enable/disable]Enable or disable DHCP client.Example:ipconfig dhcp enableipconfig dns1 ADDRESSSet primary DNS to ADDRESS, disable getting DNS from DHCP if enabled.Example:ipconfig dns1 192.168.100.1ipconfig dns2 ADDRESSSet secondary DNS to ADDRESS, disable getting DNS from DHCP if enabled.Example:ipconfig dns2 1.1.1.1
eth_maceth_mac helpPrint the help message.eth_mac defaultSet device’s MAC address to factory-default one.eth_mac set MAC_ADDRSet device’s MAC address to MAC_ADDR. Accepts both dash and colon-separated formats.Example:eth_mac set 01-02-03-04-05-06Example:eth_mac set 01:02:03:04:05:06
http_porthttp_port helpPrint the help message.http_port PORT_NUMBERSet http port to PORT_NUMBER. A PORT_NUMBER value must be in range: 1-65535.Example:http_port 80http_port statusPrint current http port.Example:http_port statusA current http port is 80
telnet_porttelnet_port helpPrint the help message.telnet_port PORT_NUMBERSet Telnet port to PORT_NUMBER. A PORT_NUMBER value must be in range: 1-65535.Example:telnet_port 23telnet_port statusPrint current Telnet port.Example:telnet_port statusA current telnet port is 23
modbus_tcp_portmodbus_tcp_port helpPrint the help message.modbus_tcp_port PORT_NUMBERSet http port to PORT_NUMBER. A PORT_NUMBER value must be in range: 1-65535.Example:modbus_tcp_port 502modbus_tcp_port statusPrint current Modbus port.Example:modbus_tcp_port statusA current modbus port is 502
Changing username or password
To change username or password, use user command.{{@176#bkmrk-port_number-is-a-num}}
Available commands:{{@176#bkmrk-modbus_routing-modbu}}
user helpPrint the help message.user mod_name USER_NAME NEW_NAMEChange the user name to NEW_NAME. It fails if the name is used by another user.Example:user mod_name admin NEW_NAMEuser passwd USER_NAMEChange USER_NAME's password.Example:user passwd admin****** <- here is entered password, but '*' appears insteadNote: Everyone can change the password for themselves.
Configuration by the Telnet Console
Access to the Telnet console can be obtained using a serial terminal program. Configure the connection type to Telnet, enter the IP address and Telnet port number (23 by default).
Console commands are the same as ones described in the serial console section.
Reset to Factory Defaults
Reset to factory defaults is possible on the web page in the device section or using the service mode.
Service mode
Procedure to enter service mode for G01 - G03 gateways
- Turn off the power of the device.
- Connect Ethernet converter to the dedicated USB/UART converter via the microUSB port.
- Connect the USB/UART converter to the PC.
- Open the serial console (default baud rate is 115200 bps).
- Press and hold the S1 button.
- Turn on the power.
- Wait until the ST indicator (red LED) lights up.
- Release the S1 button.
- If the process is successful, service commands can be typed into the terminal.
Procedure to enter service mode for G14 - G16 gateways
- Install STM32 Virtual COM Port Driver (if it was not done before).
- Turn off the power of the device.
- Connect Ethernet converter directly to the PC (the dedicated USB/UART converter is not obligatory).
- Open the serial console (default baud rate is 115200 bps).
- Press and hold the S1 button.
- Turn on the power.
- Wait until the ST indicator (red LED) lights up.
- Release the S1 button.
- If the process is successful, service commands can be typed into the terminal.