Features
|
Introduction
C01 - C04 family products are reliable M-Bus electrical standard converters. They enable communication in master mode with up to 10 simultaneously connected slave devices. Dedicated EMC integrated circuits guarantee improved connection quality by limiting the impact of interferences typical for an industrial environment.
Specifications
Redisage PN |
C01 |
C02 |
C03 |
C04 |
|
---|---|---|---|---|---|
Converter ports | Serial | 1 x passive RS232 | 1 x active RS232 | 1 x RS485 | 1 x active RS232/RS485 |
M-Bus | 1 x M-Bus master with up to 10 x slaves | ||||
Power |
Voltage |
12-30 VDC / 24 VAC |
|||
Power | < 1W | ||||
Frame ground connection | yes | ||||
Serial |
RS232 | TxD, RxD, GND | |||
RS485 | A, B | ||||
M-Bus | MBus+, MBus - | ||||
3000 VDC isolation sIide |
N/A |
RS232 |
RS485 |
RS232/RS485 |
|
1000 VDC isolation sIide | RS232 | N/A | |||
Baud rate |
up to 9600 bps |
||||
LED indicators | communication Tx, Rx, power | ||||
RS232 OK | N/A | ||||
RS485 termination | 120 ohm manually enabled | ||||
Connector | RS232 | 3 pin terminal block max. 2.5mm2 wire | |||
RS485 | 3 pin terminal block max. 2.5mm2 wire | ||||
Power | 3 pin terminal block max. 2.5mm2 wire | ||||
M-Bus | 3 pin terminal block max. 2.5mm2 wire | ||||
Transmission |
RS485 |
max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps |
|||
RS232 | max. 15 m at 115.2 kbps | ||||
M-Bus | see: M-Bus max. transmission distance |
||||
Mounting and enclosure | DIN rail, plastic PA - UL 94 V0, black/green | ||||
Temperatures | -40°C to +75°C operating and storage |
||||
Humidity | 10 - 90% RH, non-condensing | ||||
ESD protection |
±4 kV contact discharge / ±8 kV air discharge |
||||
Certification | CE, RoHS |
M-Bus max. transmission distance
Applications
C01 - MBus10 Converter to RS232
C02 - MBus10 Converter with active RS232 interface
C03 - MBus10 Converter to RS485
C04 - MBus10 Converter to RS232/RS485 with active RS232 interface
Frame ground FG
Electronic circuits are constantly prone to electrostatic discharge ESD.
Redisage Electronics modules feature a design for the frame ground terminal block FG.
The frame ground provides a path for bypassing ESD, which provides enhanced static protection ESD abilities and ensures the module is more reliable.
Connecting FG terminal block to the earth ground will bypass the ESD disturbances outside the device so will provide a better level of protection against ESD.
Frame Ground FG connection reference drawing is provided below.
If earth ground is not availabe FG can be left floating or it can be connected with power supply GND.
Pin assignments
C01 |
C02 |
C03 |
C04 |
Enclosure dimensions
1U Module Enclosure.
98 x 56.4 x 17.5
Units: mm.
Additional notes
Related information and links | ||
Ordering information | Accessories | Similar products |
Products family sample photo
DISCLAMER NOTES
ALL PRODUCT, PRODUCT SPECIFICATIONS, AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.