Hardware
Features
Frame ground FG
Electronic circuits are constantly prone to electrostatic discharge ESD. Redisage Electronics modules feature a design for the frame ground terminal block FG. The frame ground provides a path for bypassing ESD, which provides enhanced static protection ESD abilities and ensures the module is more reliable. Connecting FG terminal block to the earth ground will bypass the ESD disturbances outside the device so will provide a better level of protection against ESD.
Frame Ground FG connection reference drawing is provided below.
If earth ground is not available FG can be left floating or it can be connected with the power supply GND.
Specifications
Redisage PN |
P01 |
P02 |
|
---|---|---|---|
Ports |
RS232/RS485 |
2x |
|
Microcontroller |
ESP32 |
||
WiFi |
N/A |
802.11 b/g/n 150 Mbps / 2.4 GHz |
|
Bluetooth |
N/A |
v4.2 BR/EDR and BLE |
|
SMA socket connector for WiFi/BT antenna |
|
|
|
Tactile switch |
|
|
|
Power |
Voltage |
12-30 VDC |
|
Power |
< 1 W |
||
Frame ground protection |
yes |
||
Baud rate |
up to 115200 bps |
||
LED indicators |
power, link activity, programmable RGB |
||
RS485 termination |
120 ohm manually enabled |
||
Connector |
RS232/RS485 |
8 pin terminal block max. 2.5 mm2 wire |
|
Power |
3 pin terminal block max. 2.5 mm2 wire |
||
Ethernet |
RJ45 |
||
Transmission |
RS485 |
max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps |
|
RS232 |
max. 15 m at 115.2 kbps |
||
Mounting and enclosure |
DIN rail, plastic PA - UL 94 V0, black/green |
||
Temperatures |
-40°C to +75°C operating and storage |
||
Humidity |
10 - 90% RH, non-condensing |
||
ESD protection |
±4 kV contact discharge / ±8 kV air discharge |
||
Certification |
CE, RoHS |
Pin assignments
P01 (...) |
P02 (...) |