Procedures Configuration by the Serial Console Procedure to enter serial console mode on C30 - C32 Turn off the power of the device. Connect Ethernet converter to the dedicated USB/UART converter via the microUSB port. Connect USB/UART converter to the PC. Open the serial console (default baud rate is 115200 bps). Short the FG and GND ports. Turn on the power. Wait until the ST indicator ( orange  LED) lights up (it should light up after red light - service mode). Open the the DI and GND ports. Login using user’s personal credentials or default login details. If the process is successful, configuration commands can be typed into the terminal. Redisage Configurator Configuration procedure Change the device port service to the RemoteCOM.  Set up a port number. Enable or disable encryption. If encryption is enabled create a password. In the Redisage Configurator click add the device and then set the COM number and the service port. If encryption is enabled enter a password. Click save changes. Connect to the configured serial COM port via terminal software. Service mode Procedure to enter service mode for C30 - C32 converters Turn off the power of the device. Connect Ethernet converter to the dedicated USB/UART converter via the microUSB port. Connect the USB/UART converter to the PC. Open the serial console (default baud rate is 115200 bps). Short the DI and GND ports. Turn on the power. Wait until the ST indicator ( red LED) lights up. Open the the DI and GND ports. If the process is successful, service commands can be typed into the terminal.