RemoteCOM (Serial Port Server) with Wi-Fi®

C30 - C32 Serial Port Server Ethernet 10/100 MB + Wi-Fi® b/g/n documentation

Data Sheet

Serial Port Server w/ Wi-Fi® (C30 - C32)

Serial Port Server is a complete hardware and software solution for creating remote communication ports. The software part can be uploaded to any of the Redisage C30 - C32 Ethernet Converters. It provides a communication between a LAN host and a device equipped with RS232/RS485 serial interfaces. A dedicated app makes it easy and fast to configure and deploy. There is a possibility to create virtual COM ports with the Redisage Configurator to minimize number of cables. Onboard Wi-Fi module makes it even more versatile and independent solution.

C30 C31 C32

eng_pl_C30-Wi-Fi-802-11bgn-Ethernet-10-100MB-2xRS232-Converter-28_2 (1).jpg

Features

  • Ethernet converter to RS232/RS485
  • ESD protection for the RS485 data line
  • Power supply: +12 to +30 VDC
  • Transmission speed up to 115200 bps
  • Tx, Rx and power LED indicators
  • RS485 embedded termination 120 ohm
  • WiFi 802.11b/g/n 150 Mbps / 2.4 GHz
  • Operating temperatures: -40°C to +75°C
  • DIN rail mounting
  • Dimensions: 90x56.4x22.5 mm
  • 3 years warranty
  • Customization of OEM is welcomed

Introduction

C30 - C32 are a products family of reliable converters based on the ESP32 Xtensa LX6 microcontroller, extending the capabilities of industrial devices.

The addition of a network interface allows remote access and full control over a communication via a computer.

The user performs the basic configuration of transmission parameters in a browser or via a Telnet/serial console. 

Dedicated EMC integrated circuits guarantee improved connection quality by limiting the impact of the interferences typical for an industrial environment.

Specifications

Redisage PN

C30

C31

C32

Ports

RS232

2x

-

-

RS485

-

1x

-

RS232/RS485

-

-

2x

Microcontroller

ESP32

WiFi

802.11b/g/n 150 Mbps / 2.4 GHz

Power

Voltage

12-30 VDC

Power

< 1 W

Frame ground connection

yes

Baud rate

up to 115200 bps

LED indicators

communication Tx, Rx and power

RS485 termination

120 ohm manually enabled

Connector

RS232/RS485

8-pin terminal block max. 2.5 mm2 wire

Power

3-pin terminal block max. 2.5 mm2 wire

Ethernet

RJ45

Transmission
distance

RS485

max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps
(Belden 9841 2P twisted-pair cable, if different cables are used, the transmission distance may change)

Mounting and enclosure

DIN rail, plastic PA - UL 94 V0, black/green

Temperatures

-40°C to +75°C operating and storage

Humidity

10 - 90% RH, non-condensing

ESD protection

±4 kV contact discharge / ±8 kV air discharge

Certification 

CE, RoHS, RED

Norms

61000-6-2 – Immunity standard for industrial environments
61000-6-4 – Emission standard for industrial environments
EN 300 328 – Data transmission equipment operating in the 2,4 GHz
band

Variants

C30 - Serial Port Server (2x RS232) + Wi-Fi

C31 - Serial Port Server (1x RS485) + Wi-Fi

C32 - Serial Port Server (2x RS232/RS485) + Wi-Fi

* In the C32 converter user should use only RS232 or only RS485 interface of one port as they occupy the same internal bus of the device. It means, don't use pairs: RS232-1 & RS485-1 at the same time and RS232-2 & RS485-2 at the same time!

Frame ground FG

Electronic circuits are constantly prone to electrostatic discharge ESD. Redisage Electronics modules feature a design for the frame ground terminal block FG. The frame ground provides a path for bypassing ESD, which provides enhanced static protection ESD abilities and ensures the module is more reliable. Connecting FG terminal block to the earth ground will bypass the ESD disturbances outside the device so will provide a better level of protection against ESD.

Frame Ground FG connection reference drawing is provided below.

If earth ground is not available FG can be left floating or it can be connected with the power supply GND.

Pin assignments

C30

10c2519f-3c2b-43dd-b8dd-0d4c1b3ed8b0.jpg

C31

4e765dfc-6ad8-4aa7-a896-b838cd3c45e7.jpg

C32

6ebcae2c-6a07-4575-9d71-160c02fc6846.jpg

LED indicators

Converters C30 - C32

image.png


LED indicator

Color

Function

PW

Blue

Power

ETH

Green

Network activity

ST

Orange

Console mode

Red

Service mode

Enclosure dimensions

2U Module Enclosure
98 x 22.5 x 56.4
Units: mm

image (3).webp

Getting started

Power supply

Ethernet converters C30 - C32 have wide voltage power input (12-30 VDC) and the power consumption is less than 1 W.

Check user manual before first launch.

Reset to Factory Defaults

Reset to factory defaults is possible on the web page in the device section or using the service mode. 

Service mode

Procedure to enter service mode for C30 - C32 converters

List of commands in the service mode

Command

Description

help

Print the help.

credits

Print current credits value for this device.

dev_ident

Print the device identification value.

restart

Restart the system.

serial_num

Print the serial number of this device.

version

Display the bootloader version.

xmodem

Download image to the internal flash using xmodem.

defaults

Reset application variables to defaults.

ipconfig

Print or change the network configuration.

flash_read

Read bytes from flash memory.

md

Read bytes from memory address.

In the service mode, the “ipconfig” command can only show a last static IP address.

Additional notes

Wi-Fi® is a registered trademark of Wi-Fi Alliance®.

Products family sample photo

https://redisage.com

DISCLAMER NOTES
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Datasheet-ID: 

SR-D

User Manual

RemoteCOM w/ Wi-Fi (C30 - C32)

User Manual

Introduction

Serial Port Server w/ Wi-Fi® (C30 - C32)

Serial Port Server is a complete hardware and software solution for creating remote communication ports. The software part can be uploaded to any of the Redisage C30 - C32 Ethernet Converters. It provides a communication between a LAN host and a device equipped with RS232/RS485 serial interfaces. A dedicated app makes it easy and fast to configure and deploy. There is a possibility to create virtual COM ports with the Redisage Configurator to minimize number of cables. Onboard Wi-Fi module makes it even more versatile and independent solution.

eng_pl_C30-Wi-Fi-802-11bgn-Ethernet-10-100MB-2xRS232-Converter-28_4.jpg

User Manual

Configuration by the Web Page

Serial Port Server w/ Wi-Fi® (C30 - C32)

This page presents capabilities of the Ethernet Converters configuration. First of all, make sure that converter is connected to power supply and to the LAN using a patch cord. If the device has not static IP set up, it will be necessary to obtain its IP address in the local network. User interface is mostly similar for every converters but some subpages might be diffrent for several models depends on amount of interfaces. In order to avoid some issues, click on a “Help” button in the top right corner on every page.

Default configuration

Default configuration of the Ethernet Converters:

Default login details:


Login

To access the web page open the browser, type IP address of the converter (default is 192.168.100.100). Then log in using user’s personal credentials. If it is a first configuration or the converter had a factory reset, then use default login details (login: admin, password: admin123).

image.png

The configuration is available only if devices are connected to the same Local Area Network as the computer used for it.

Status page

After a successful login, there should be an insight to important information such as port status, service and port which are in use and more details about the connection.

image.png

Changing username or password

After clicking “Edit User” under the user icon, it is possible to change the username or the password.

image.png

67bf69dd-bb1e-47f7-8135-4d13cac96cab.png

If login details were forgotten, it would be necessary to do a factory reset via a USB/UART converter and a serial console.

Ports page

This page allows configuring the device’s ports. There is a toggle switch next to a “Port” label by which it is possible to turn ON/OFF any particular ports.

image.png


Item

Description

Service

RemoteCOM

The RemoteCOM option lets to attach the port to a computer running the Redisage Configurator as if it would be physically present in the computer.

TCP Socket

TCP/UDP Socket exposes this port as a regular network socket - connect to this socket with own software and write/read data to send/receive data over the serial port without any additional software or serial port handling.

UDP Socket

Port

The service number - the device has an “IP Address” by which it is identified and a couple of services running on it. It's required to tell the device which service should be in use by entering this device's IP address and the port number in the RemoteCOM client or user’s software.

Connection Timeout [s]

The time specifying how often (every how many seconds) the "keep alive" packet will be sent to check if the client is still connected. Value 0 means that the connection is kept permanently without any timeout.

Inactivity Time [ms]

The maximum allowed time in milliseconds during which there is no data transfer. When connection is inactive for the time longer or equal to the entered value, then it will be closed. Value 0 means there is no measure of the inactivity time at all.

Encryption

Determine how the data is protected 'in flight' over a network. It is available only with the RemoteCOM service. Once enabled, it is necessary to set the password.

Password

Protect the communication between the device and various clients - keep it secret! Same settings have to appear in clients - without the correct passwords, a client will not be able to connect at all.

Termination

Enable/disable termination on the RS line.

Baud Rate

Determine the port's transmission speed over the data channel.

Data Bits

Determine the number of data bits in the port's message frame.

Parity

Enable/disable parity check in the port's message frame.

Stop Bits

Determine the number of stop bits in the port's message frame.

Notes

These notes are for information only - feel free to write down anything related to this port (device it connects to, etc.). They're also shown in the Configurator during the device discovery - in the other words, they're public.

Changing port’s service closes all sockets connected to the ports.

In the UDP mode, port number 15051 is reserved for UDP broadcast service.

Network page

In this section, network settings can be changed according to target LAN parameters.

image.png

image.png

Item

Description

Configuration Method

Enable/disable the DHCP server. If the DHCP server is disabled, the IP address of the device has to be set manually.

IP Address

IP address of the device.

Netmask

Netmask associated with the IP address.

Gateway

Gateway address currently used by the device.

MAC Settings

Allow setting the default MAC address or typing it manually.

MAC Address

Allow changing the physical address of the device.

image.png

Item

Description

HTTP Port

Determine the port of the control panel.

Telnet Port

Allow connection with the device via Telnet.

Broadcasts

Notify RemoteCOM clients in the same network about this device's existence. With this enabled, the Configurator will automatically set most of the settings correctly after picking the correct port.

Hostname

Label that is assigned to the device.

DNS Address 1 (Primary)

Primary Domain Name System used by the device.

DNS Address 2

Domain Name System used by the device.

It is possible to obtain a dynamic IP address. Just switch configuration method from static IP to DHCP (automatic). This process may cause some issues with identifying converters in LAN unless there is an access to the device which is responsible for allocating IP addresses.

Keep in mind that in case of changed IP address user needs to type new IP in the address bar and log in again.


Device page

On the device page there are tools used to a firmware update, a factory reset and a device reboot.

image.png

Item

Description

Firmware Update

Update firmware.

Factory Reset

Restore default ports settings and default network configuration.

Reboot

Reboot the device.

Firmware update

The device firmware update must not be interrupted. Update the device only if experiencing issues, being instructed to do so by our support or requiring the latest features/bugfixes. Failure during the update may 'brick' the device and make it unusable.

image.png

Use the remote-com-esp32.fir file for a firmware update.

Factory reset

To restore default settings, press the “Factory Reset” button. After that, user will be asked to type “RESET”. Then it will take a few seconds to reload the web page and restart the device.

image.png


User Manual

Configuration by the Telnet Console‎

Serial Port Server w/ Wi-Fi® (C30 - C32)

The device can be also configured via the Telnet Console. Firstly, make sure that converter is connected to the power supply and to the LAN using a patch cord. Knowledge of the device’s IP address (default is 192.168.100.100) and Telnet port number (default is 23) is necessary to establish a connection.

Use command below in a terminal window to connect to the device:

telnet <ip_address> <port_number>

If the connection is successful there will be a login prompt visible. Log in using user’s personal credentials or the default login details (login: admin, password: admin123). If login is successful, it will be possible to start typing configuration commands.

0e6873d5-31dd-4050-9c0b-e87fcaa271e4.png

The configuration is available only if devices are connected to the same Local Area Network as the computer used for it.

List of all commands

Command

Description

help

Print the help.

conn

Print active TCP connections.

eth_mac

Print or change MAC address.

exit

Close current CLI session.

http_port

Print or change default http port.

ipconfig

Print or change the network configuration.

net_stat

Print lwIP statistics.

ping

Check internet connection with the desired host.

restart

Restart the system.

reboot

Same as restart.

sys_heap_usage

Print current heap usage.

telnet_port

Print or change default telnet port.

uart

Print or change uart configuration.

uart_service

Print or change uart_service configuration.

user

Print or change user configuration.

wificonf

Print or change the Wi-Fi configuration

wifi_mac

Print or change Wi-Fi MAC address.

Ports configuration commands

In terms of ports configuration it is possible to change parameters like: service, baud rate, data bits, parity, stop bits and so on. UART commands are provided below.

Network settings

The following commands might be helpful to change network settings according to target LAN parameters. 

Changing username or password

To change username or password, use user command. Available commands:

Additional notes

After some time of inactivity, session will be disconnected automatically.

In order to avoid issues like connecting to the host, type “help” to get more information.

To get more details about every particular command, append “help” after each commands (example: "ipconfig help").

Factory reset is not available from the Telnet Console level.

User Manual

Configuration by the Serial Console‎

Serial Port Server w/ Wi-Fi® (C30 - C32)

Another way to configure the device is via a serial console. C30 - C32 require a dedicated USB/UART converter connected to the USB micro-B connector on the front of the device (check our converters).

Procedure to enter serial console mode on C30 - C32

Once this is done, log in using the default username and password, then change the network settings using "ipconfig" command.

5875417d-264b-4abb-bdcd-4ea4e558bd5a.png

List of all commands

Command

Description

help

Print the help.

conn

Print active TCP connections.

eth_mac

Print or change MAC address.

exit

Close current CLI session.

http_port

Print or change default http port.

ipconfig

Print or change the network configuration.

net_stat

Print lwIP statistics.

ping

Check internet connection with the desired host.

restart

Restart the system.

reboot

Same as restart.

sys_heap_usage

Print current heap usage.

telnet_port

Print or change default telnet port.

uart

Print or change uart configuration.

uart_service

Print or change uart_service configuration.

user

Print or change user configuration.

wificonf

Print or change the Wi-Fi configuration

wifi_mac

Print or change Wi-Fi MAC address.

Ports configuration commands

In terms of ports configuration it is possible to change parameters like: service, baud rate, data bits, parity, stop bits and so on. UART commands are provided below.

Network settings

The following commands might be helpful to change network settings according to target LAN parameters. 

Changing username or password

To change username or password, use user command. Available commands:

Service mode

Procedure to enter service mode for C30 - C32 converters

List of commands in the service mode

Command

Description

help

Print the help.

credits

Print current credits value for this device.

dev_ident

Print the device identification value.

restart

Restart the system.

serial_num

Print the serial number of this device.

version

Display the bootloader version.

xmodem

Download image to the internal flash using xmodem.

defaults

Reset application variables to defaults.

ipconfig

Print or change the network configuration.

flash_read

Read bytes from flash memory.

md

Read bytes from memory address.

In the service mode, the “ipconfig” command can only show a last static IP address.

Factory reset

To restore default settings, type “defaults”. After that, user will be asked to type “default network” to reset the network settings as well. Then user will be informed if the process is successful.

Additional notes

In order to avoid issues like connecting to host, type “help” to get more information.

To get more details about every particular command, append “help” after each commands (example: "ipconfig help").

User Manual

Redisage Configurator‎

Serial Port Server w/ Wi-Fi® (C30 - C32)

Redisage Configurator is an app used to emulate connection between converter and a PC as if its RS232/RS485 ports would be connected directly to the COM port. The advantage of that functionality is lack of additional cables. Transmission can be tested over Ethernet. First connect the device to a local network using the Ethernet port and power it up. During the configuration process set “Service” to the RemoteCOM option on the “Ports” page.

While changing port service from RemoteCOM to TCP/UDP Socket make sure to disable RemoteCOM virtual port in the Redisage Configurator first.

image.png

Redisage VSP Driver

In order for Redisage Configurator to work properly, it is necessary to install the Redisage VSP Driver. It can be done with RedisageVSPDriver Installer available for Windows. You can download it for free here.

4e06a5a0-4a26-4fb3-b676-8b6d856b08d2.png

Redisage Configurator

When the device is configured open the Redisage Configurator app.

11350c46-7007-4fcb-add1-062c5c31ef21.png

Use the “Add Device” button to set up a new connection with a device. On the right side there should be a list of available devices visible. Choose one of them or specify a custom COM port number, an IP address and a service port number.

While specifying a custom virtual COM make sure to use the same IP address and service port as set earlier in the port configuration.

7d9e3ea8-6904-4f6d-b072-47b15c80d60c.png

In order to establish a connection with a desired device use the “Enable” button. To end the connection use the “Disable” button. Service IP/hostname, service port and password can be modified at any time. There are also available 2 options of the encryption methods (none (disabled) or strong (AES-GCM 128-bit, Argon2)) and 5 options of the connection timeout (brief, short, fair, modest or lengthy). Changes have to be saved with “Save Changes” button.

434ace32-b439-47be-b821-da79cef2b770.png

There is also the “Settings” tab at the top of the window from where the Logging Directory or the Device Manager can be opened.

ae6fd1d6-457d-4da4-82bc-99785acd103f.png

If everything is connected properly there should be a new COM port available in the Device Manager. It is also possible to check it, for example, on the web page.

If any change is made to the port configuration, make sure to apply it with the “Save Changes” button.

Troubleshooting

If a discovered device cannot be added, check if it hadn’t been added before with a different COM port / service port. In that case, delete previous configuration from the Redisage Configurator.

If that doesn't work, check if the port service was configured correctly for the RemoteCOM Service.

Modes of Operation

RemoteCOM Serial Port Server + Wi-Fi (C30 - C32)

Modes of Operation

TCP Socket Mode

Serial Port Server w/ Wi-Fi (C30 - C32)

This article presents a simple instruction of a first connection between a TCP client and a RS232/485 device through the RemoteCOM Serial Port Server. Firstly, connect the RemoteCOM according to the diagram below.

Then, it is necessary to configure the RemoteCOM’s ports. It can be done, for example, via the device’s web page. Ports' configuration can also be done via the Telnet, serial or service console. Set the “TCP Socket” option in the “Service” field on the “Port” page. Check also if the port number is set correctly in the “Port” field. Set desired options of the RS232/485 connection (“Baud Rate”, “Data Bits”, “Parity”, “Stop Bits” - these options should be the same as in the RS232/485 device).

518960b3-054f-491f-afab-5ad319c53274.png

Now, the device should be ready to work. Once the TCP Client creates a TCP socket, the bidirectional communication should be available.

Test connection

Connection can be easily tested with a USB-RS232/485 converter and for example Hercules Setup Utility software. Connect the RemoteCOM’s RS232/485 port to the USB-RS232/485 converter and plug it in to the USB port of a PC. Open Hercules Setup Utility program and go to the “Serial” page. Set serial connection options according to the previous RemoteCOM’s ports configuration and open the COM port. Then, go to the “TCP Client” page and set the device’s IP address and port. After a successful connection, there should be the bidirectional communication available.

df091a6c-b716-4a25-800a-123a10bcb250.png

Modes of Operation

UDP Socket Mode

Serial Port Server w/ Wi-Fi (C30 - C32)

This article presents a simple instruction of a first connection between a UDP client and a RS232/485 device through the RemoteCOM Serial Port Server. Firstly, connect the RemoteCOM according to the diagram below.

Then, it is necessary to configure the RemoteCOM’s ports. It can be done, for example, via the device’s web page. Ports' configuration can be also done via the Telnet, serial or service console.  Set the “UDP Socket” option in the “Service” field on the “Port” page. Check also if the port number is set correctly in the “Port” field. Set desired options of the RS232/485 connection (“Baud Rate”, “Data Bits”, “Parity”, “Stop Bits” - these options should be the same as in the RS232/485 device).

63525652-3521-4885-aa5a-6af998d9a2d0.png

Now, the device should be ready to work. The bidirectional communication should be available after the device receiving a first message from the UDP client. Before that happens, all the data sent from the device to the UDP client will be buffered and sent later.

Test connection

Connection can be easily tested with a USB-RS232/485 converter and for example Hercules Setup Utility software. Connect the RemoteCOM’s RS232/485 port to the USB-RS232/485 converter and plug it in to a USB port of a PC. Open Hercules Setup Utility program and go to the “Serial” page. Set serial connection options according to the previous RemoteCOM’s ports configuration and open the COM port. Then, go to the “UDP” page and set the device’s IP address and port. The bidirectional communication should be available after the device receiving a first message from the UDP client. Before that happens, all the data sent from the device to the UDP client will be buffered and sent later.

c14dca73-45f9-419f-8a05-adfe46536a19.png

Modes of Operation

Redisage Configurator Virtual COM Mode

Serial Port Server /w Wi-Fi (C30 - C32)

This article presents a simple instruction of a first connection between a virtual COM port and a RS232/485 device through the RemoteCOM Serial Port Server and the Redisage Configurator app. Redisage Configurator is used to emulate connection between converter and a PC as if its RS232/RS485 ports would be connected directly to the COM port. The advantage of that functionality is lack of additional cables. Redisage Configurator can be installed on Windows machine and requires the Redisage VSP Driver to work (it can be installed with RedisageVSPDriver Installer). 

In order to perform a setup, connect the RemoteCOM according to the diagram below (RemoteCOM should be connected via Ethernet to the same local network as the PC).

Then, it is necessary to configure the RemoteCOM’s ports. It can be done, for example, via the device’s web page. Ports' configuration can also be done via Telnet, serial or service console.  Set the “RemoteCOM” option in the “Service” field on the “Port” page. Check also if the port number is set correctly in the “Port” field. Additionally, encryption can be set to increase the security (it will also require to set up a password).

6f9c3d38-2582-4c34-ad2d-ab836d769687.png

Next, open the Redisage Configurator and click the “Add Device…” button. Available RemoteCOM’s ports should appear on the list. Choose the desired one and click the “Add” button.

d3ba1f43-7a53-44d4-832a-bd1f94849812.png

If a discovered device cannot be added, check if it hadn’t been added before with a different COM port / service port. In that case, delete previous configuration from the Redisage Configurator.

If that won’t work, check if the port service was configured correctly for the RemoteCOM Service.

Enable the virtual COM port with the “Save changes” button. If a password was set during the configuration, it will be necessary to type it into the “Password” field.

e19b5421-ac8b-4550-a294-483993959714.png

Now, the device should be ready to work. The bidirectional communication should be available from the start. It is possible to check if created virtual COM port is present in the system. Just go to the “Settings” page and choose “Open Device Manager” button. There should be a “Redisage” COM visible.

ae6fd1d6-457d-4da4-82bc-99785acd103f.png

020d37e6-2e08-489b-8ee5-ee3b9dc9ecad.png

Test connection

Connection can be easily tested with a USB-RS232/485 converter and for example Hercules Setup Utility software. Connect the RemoteCOM’s RS232/485 port to the USB-RS232/485 converter and plug it in to a USB port of a PC. Open 2 instances of Hercules Setup Utility program and go to the “Serial” page of the first one. Set serial connection options according to the previous RemoteCOM’s ports configuration and open the COM port (fixed options: Baud Rate 115200; Data Bits: 8; Parity: None; Stop Bits: 1).

Then, go to the “Serial” page of the second Hercules instance and set the virtual COM port in the same way as the serial port of the first Hercules instance. After a successful connection, there should be the bidirectional communication available.

4bc9a829-b72c-4178-9877-26c1a60616e6.png

While changing port service back from RemoteCOM to TCP/UDP Socket make sure to disable RemoteCOM virtual port in the Redisage Configurator first.

Contact Us

Common Resources

Source of common resources used across the RemoteCOM w/ Wi-Fi documentation

Common Resources

Tables

Specifications

Redisage PN

C30

C31

C32

Ports

RS232

2x

-

-

RS485

-

1x

-

RS232/RS485

-

-

2x

Microcontroller

ESP32

WiFi

802.11b/g/n 150 Mbps / 2.4 GHz

Power

Voltage

12-30 VDC

Power

< 1 W

Frame ground connection

yes

Baud rate

up to 115200 bps

LED indicators

communication Tx, Rx and power

RS485 termination

120 ohm manually enabled

Connector

RS232/RS485

8-pin terminal block max. 2.5 mm2 wire

Power

3-pin terminal block max. 2.5 mm2 wire

Ethernet

RJ45

Transmission
distance

RS485

max. 1,200 m at 9.6 kbps; max. 400 m at 115.2 kbps
(Belden 9841 2P twisted-pair cable, if different cables are used, the transmission distance may change)

Mounting and enclosure

DIN rail, plastic PA - UL 94 V0, black/green

Temperatures

-40°C to +75°C operating and storage

Humidity

10 - 90% RH, non-condensing

ESD protection

±4 kV contact discharge / ±8 kV air discharge

Certification 

CE, RoHS, RED

Norms

61000-6-2 – Immunity standard for industrial environments
61000-6-4 – Emission standard for industrial environments
EN 300 328 – Data transmission equipment operating in the 2,4 GHz
band

Pin assignments

C30

10c2519f-3c2b-43dd-b8dd-0d4c1b3ed8b0.jpg

C31

4e765dfc-6ad8-4aa7-a896-b838cd3c45e7.jpg

C32

6ebcae2c-6a07-4575-9d71-160c02fc6846.jpg

Configuration by the Web Page

Ports page

Item

Description

Service

RemoteCOM

The RemoteCOM option lets to attach the port to a computer running the Redisage Configurator as if it would be physically present in the computer.

TCP Socket

TCP/UDP Socket exposes this port as a regular network socket - connect to this socket with own software and write/read data to send/receive data over the serial port without any additional software or serial port handling.

UDP Socket

Port

The service number - the device has an “IP Address” by which it is identified and a couple of services running on it. It's required to tell the device which service should be in use by entering this device's IP address and the port number in the RemoteCOM client or user’s software.

Connection Timeout [s]

The time specifying how often (every how many seconds) the "keep alive" packet will be sent to check if the client is still connected. Value 0 means that the connection is kept permanently without any timeout.

Inactivity Time [ms]

The maximum allowed time in milliseconds during which there is no data transfer. When connection is inactive for the time longer or equal to the entered value, then it will be closed. Value 0 means there is no measure of the inactivity time at all.

Encryption

Determine how the data is protected 'in flight' over a network. It is available only with the RemoteCOM service. Once enabled, it is necessary to set the password.

Password

Protect the communication between the device and various clients - keep it secret! Same settings have to appear in clients - without the correct passwords, a client will not be able to connect at all.

Termination

Enable/disable termination on the RS line.

Baud Rate

Determine the port's transmission speed over the data channel.

Data Bits

Determine the number of data bits in the port's message frame.

Parity

Enable/disable parity check in the port's message frame.

Stop Bits

Determine the number of stop bits in the port's message frame.

Notes

These notes are for information only - feel free to write down anything related to this port (device it connects to, etc.). They're also shown in the Configurator during the device discovery - in the other words, they're public.

Network page

Item

Description

Configuration Method

Enable/disable the DHCP server. If the DHCP server is disabled, the IP address of the device has to be set manually.

IP Address

IP address of the device.

Netmask

Netmask associated with the IP address.

Gateway

Gateway address currently used by the device.

MAC Settings

Allow setting the default MAC address or typing it manually.

MAC Address

Allow changing the physical address of the device.

Item

Description

HTTP Port

Determine the port of the control panel.

Telnet Port

Allow connection with the device via Telnet.

Broadcasts

Notify RemoteCOM clients in the same network about this device's existence. With this enabled, the Configurator will automatically set most of the settings correctly after picking the correct port.

Hostname

Label that is assigned to the device.

DNS Address 1 (Primary)

Primary Domain Name System used by the device.

DNS Address 2

Domain Name System used by the device.

Device page

Item

Description

Firmware Update

Update firmware.

Factory Reset

Restore default ports settings and default network configuration.

Reboot

Reboot the device.

Configuration by the Serial Console

List of all commands

Command

Description

help

Print the help.

conn

Print active TCP connections.

eth_mac

Print or change MAC address.

exit

Close current CLI session.

http_port

Print or change default http port.

ipconfig

Print or change the network configuration.

net_stat

Print lwIP statistics.

ping

Check internet connection with the desired host.

restart

Restart the system.

reboot

Same as restart.

sys_heap_usage

Print current heap usage.

telnet_port

Print or change default telnet port.

uart

Print or change uart configuration.

uart_service

Print or change uart_service configuration.

user

Print or change user configuration.

wificonf

Print or change the Wi-Fi configuration

wifi_mac

Print or change Wi-Fi MAC address.

List of commands in the service mode

Command

Description

help

Print the help.

credits

Print current credits value for this device.

dev_ident

Print the device identification value.

restart

Restart the system.

serial_num

Print the serial number of this device.

version

Display the bootloader version.

xmodem

Download image to the internal flash using xmodem.

defaults

Reset application variables to defaults.

ipconfig

Print or change the network configuration.

flash_read

Read bytes from flash memory.

md

Read bytes from memory address.

In the service mode, the “ipconfig” command can only show a last static IP address.

Common Resources

Commands

Ports configuration commands

In terms of ports configuration it is possible to change parameters like: service, baud rate, data bits, parity, stop bits and so on. UART commands are provided below.

Network settings

The following commands might be helpful to change network settings according to target LAN parameters. 

Changing username or password

To change username or password, use user command. Available commands:

Common Resources

Procedures

Configuration by the Serial Console

Procedure to enter serial console mode on C30 - C32

Redisage Configurator

Configuration procedure

Service mode

Procedure to enter service mode for C30 - C32 converters

Common Resources

Introduction

Serial Port Server w/ Wi-Fi® (C30 - C32)

Serial Port Server is a complete hardware and software solution for creating remote communication ports. The software part can be uploaded to any of the Redisage C30 - C32 Ethernet Converters. It provides a communication between a LAN host and a device equipped with RS232/RS485 serial interfaces. A dedicated app makes it easy and fast to configure and deploy. There is a possibility to create virtual COM ports with the Redisage Configurator to minimize number of cables. Onboard Wi-Fi module makes it even more versatile and independent solution.